Mold Simulator

software for thermal bridges, mould and condensation

2D and 3D · steady-state and transient
Frame Simulator

software for windows and curtain walls

ISO 10077-2 · ISO 12631
Available forWindowsMacinEnglish Italiano Français Deutsch Español
Version 9 · now with Claude and ChatGPT

You used to have to learn. Now you just ask.

Calculate thermal bridges and windows with an AI assistant that shows you how it is done, checks what you are doing and explains every step. The calculation sequence is the same as ever, but you no longer face it alone.

From the drawing to the simulation of a roof junction
Use cases

Ask as you would ask an expert colleague

Try these prompts

You don’t remember how it’s done (Mold Simulator)
I am a Mold PRO 2D user. I haven’t opened the program for a while and I don’t remember how to use it. I need to calculate a wall-floor junction over an unheated room: how do I proceed?
Used Heatsim ›
The program is open and connected (Mold PRO 2D, empty project): I’ll guide you one step at a time.
This is the path:
  1. Goal: what you need (Ψ, fRsi, mould and condensation check), for which use and with which dimension reference (internal or external).
  2. Geometry: from your own DXF, or from a parametric Bridge Generator template. For your case there are two groups of templates: wall with floor over an unheated room below (e.g. cellar, garage) and wall with ceiling towards an unheated room above (e.g. attic), with or without ring beam, ring beam correction, balcony, and with external, internal, cavity or no insulation.
  3. Layers and dimensions: wall and floor layers, ring beam, cut-off lengths of the model.
  4. Materials: assignment and check of the conductivities.
Read the full answerClose
  1. Boundary conditions: heated interior, exterior, unheated room, adiabatic sides, location and humidity class.
  2. Model check and simulation.
  3. Results: L2D, Ψ, fRsi, minimum surface temperature, mould and condensation views.
  4. Report as a PDF.
Before we start I need a working folder on your PC to save the project, screenshots and report.
Which folder shall I use? If you don’t have one, I suggest Documents\Mold – wall-floor junction.
You want to know where you went wrong (window laying: Mold and Frame)
Window laying.mosMOS
Check this window laying calculation in Mold and tell me where I went wrong.
Used Heatsim and 5 more steps ›
There are three real errors, and the Ψ = 0.085 W/(m·K) you get now is not the window laying Ψ.
1. The area element around the window is missing
In the Elements tab there is no closed path: instead there are three section elements (wall, frame, panel).
2. The segment material between subframe and frame is missing
Without that segment the program does not know which sides to make adiabatic when it simulates the window on its own.
3. Mould and condensation checks switched off, and wrong boundary on the frame
In the simulation settings mould and surface condensation are disabled: only the flows simulation was run, so there is no ISO 13788 verdict.
Read the full answerClose
On point 1
This way the program calculates:

Ψ = L2D − Σ U·l = 1.014 − 0.929 = 0.085 W/(m·K)

Frame and panel are subtracted as one-dimensional layers (U ≈ 1.41 and 0.88 W/(m²·K)), so the Ψ also includes the frame–panel interaction, which has nothing to do with the window laying.
  • The section elements on frame and panel must be removed, leaving only the wall one, which already correctly reaches the frame.
  • The closed path must be drawn around the window (frame + panel), excluding the subframe.
On point 2
The segment goes on the side of the wood-cement subframe in contact with the frame (x ≈ 2.668).
On point 3
The internal face of the two frame blocks has the “Internal” boundary (analysis group “wall”) instead of “Window Internal”, which is now only on the panel. With the checks re-enabled, the frame would be assessed for mould like the masonry, instead of for condensation only.
To be checked, not necessarily errors
  • Location: the climate zone is set to a town in the province of Novara, at 162 m. Please confirm it is the one of the building site.
  • Frame: it is a solid block called “Aluminium” with λ = 0.12 W/(m·K). If it is an equivalent conductivity that is fine, but it is better to rename it.
  • Wall length: it is modelled for 1.0 m from the reveal. With a thickness of 53.5 cm, ISO 10211 would require 3 times the thickness, i.e. about 1.6 m. The effect here should be small.
The rest is fine: “Window joint” scene with “Houses interior” temperature, humidity class 3, ISO 6946 air layer, gravity direction for a plan section, no unassigned boundary stretch.
I have not changed anything. You draw the closed path and the segment; then, if you like, I will fix the boundary on the frame, re-enable mould and condensation and run the simulation again.
From DXF to report, step by step (Frame Simulator)
Alu side_1.dxfDXF
I am a Frame Simulator user. I have the DXF of this thermally broken aluminium profile. Explain how to calculate Uf with Frame Simulator according to ISO 10077-2 and then follow me step by step through the calculation. Warn me if I make mistakes and suggest the corrections. At the end prepare a PDF report of the calculation, in accordance with the standard.
Used Heatsim and 6 more steps ›
Frame Simulator is open with the MCP server running, so we can work directly in the program. I have already analysed your DXF: it contains only simple lines (2,625), so there is no need to explode it. It is drawn in mm and measures about 310 × 83 mm. The glazing is drawn about 205 mm wide, which is fine: the standard requires at least 190 mm.
How to calculate Uf with Frame Simulator (EN ISO 10077-2)
The manual (chapter 6, “ISO 10077-2 calculation – example 1: Uf”) describes four steps. Here I adapt them to your profile:
  1. Project and geometry.
    • You start from a template of the “FS – Windows” series: “Window – h node” for horizontal sections, like yours, which is a side section; “Window – v node” for bottom and top sections.
    • There are two series, which differ in how air cavities are treated: series 1 with the radiosity method; series 2 with the equivalent conductivity.
    • Then you import the DXF with a scale factor of 0.001, because it is in mm.
Read the full answerClose
  1. Materials.
    • The frame is filled with the real materials: aluminium, polyamide strips, insulating inserts, EPDM gaskets.
    • The glazing must be replaced with the special “10077-2 Insulation” material (insulation panel, λ = 0.035 W/(m·K)).
    • The air chambers remain cavities: the program calculates them according to the standard.
    • The rectangle on the wall side becomes adiabatic.
  2. Boundary conditions.
    • Interior and exterior with the surface resistances of the standard.
    • Adiabatic towards the wall and on the panel cut.
    • The template already sets most of them.
  3. Check and simulation. The program calculates the conductance L2D and derives Uf with the formula of the standard:

    Uf = (Lf2D − Up·bp) / bf

    • generates the section elements by itself, i.e. the frame width bf and the panel width bp;
    • bf however must always be checked: it is measured up to the end of the frame as seen from both sides, without the gaskets.
At the end I prepare the PDF report with: the method; the boundary conditions; the materials table; the views of the section; the results.
If you make a wrong choice at any step, I will warn you and suggest the correction.
A note: the project “Alu_side_1 – Uf.frs” is already open in Frame Simulator, with no changes to save. I will not touch it: our calculation starts from a new project, saved under another name.
First step
I need a working folder on the PC, where to save the DXF, the project, the images and the report.
Which folder do you want to use? I suggest Documents\Frame Simulator\Uf calculation Alu side_1, which I will create. If you prefer, tell me another folder.
You want the solution, not just the check (Mold Simulator)
In this junction open in Mold Simulator there is a risk of mould. Assess the possible measures on geometry, materials and thicknesses so that the mould check is passed.
Used Heatsim ›
The problem does not come from the junction: it comes from the concrete wall of the floor below, which is not insulated. I ran the mould check for Forlì, Italy (internal temperature “Houses interior”, humidity class “3 Mar. unknown occupancy”). The minimum fRsi simulated in January is 0.495 against the required 0.684 , and the mould extends over 1612 mm: the whole internal face of the lower wall (30 cm of concrete with plaster only) plus the corner with the ceiling.
Simulated variants
MeasurefRsi sim.Mould
Current state0.4951612 mm
External insulation on the lower wall, 3.5 cm of rock wool0.66686 mm (corner)
5 cm external insulation0.68015 mm
6 cm external insulation0.6860 ✓ (minimal margin)
Read the full answerClose
MeasurefRsi sim.Mould
7 cm external insulation, as on the floor above0.6900 ✓
10 cm external insulation0.6990 ✓
Lower wall in 30 cm clay block instead of concrete0.63194 mm
Internal insulation on the wall only, 1.5 or 4 cm0.514 / 0.486~140 mm (the corner with the ceiling gets worse)
Internal insulation, 4 cm on the wall + 3 cm on the whole ceiling0.7530 ✓
The value 0.495 is the same given by the one-dimensional calculation of the plain wall. The floor above, with 7 cm of rock wool, passes without problems.
There is also a second weak point: the reinforced concrete slab continues into the balcony. Once the wall is insulated, the critical point moves to the corner between wall and ceiling of the room below.
Possible measures
  • Continuous external insulation on the lower wall (geometry): it is the most natural solution. A resistance of at least about 1.6 m²K/W is needed: 6–7 cm of rock wool, or about 4 cm of an insulation with λ ≈ 0.022 (PIR or phenolic). Beyond 7 cm the result improves little, because at that point the balcony slab governs.
  • Insulation of the soffit and of the edge of the balcony, connected to the external insulation (geometry): it reduces the thermal bridge of the slab and gives margin to the external insulation, which with 7 cm stays just above the limit.
  • Thermal break of the balcony (load-bearing insulating element between the balcony and the floor): it is the most effective measure on the corner, but it changes the structural design.
  • Internal insulation of the lower wall: it only works with a return on the ceiling. Without the return the corner gets worse. With the whole ceiling insulated the check is passed with a wide margin; a return of limited length (50–60 cm) must be verified by drawing it. In this case the Glaser check behind the insulation is also needed.
  • Materials only, without insulation: rebuilding the wall in clay block is not enough.
How I simulated the variants
  • I did not draw the thicknesses. I simulated them by giving the existing layers an equivalent λ with the same resistance: for the external insulation the 3.5 cm external render layer, for the internal insulation the internal plasters. With the geometry drawn the values will change only slightly.
  • In these variants warning W0025 appeared: a temperature below the external one in the external corner under the balcony. It is local, it comes from the equivalent λ and does not affect the internal surface. In fact the results are the same with high and very high quality.
State of the model
  • I enabled the mould check in the simulation settings: before there were only the flow results.
  • I restored the original materials. In the materials list concrete, external render and internal plaster now appear twice, with identical properties.
  • I did not save the file.
I considered the room under the floor as heated, because it has the “Internal” boundary. Can you confirm? If instead it is a garage or an unheated room, the check changes completely. If you draw the external insulation with the return on the soffit, or the thermal break, I will simulate them and tell you the real margin.
Ask what you would ask technical support: “Where do I start?” “Have I set everything up correctly?” “What does this error mean?” “Which number goes in the report?”
The versions of Mold Simulator and Frame Simulator

2D or 3D, steady-state only or transient too

2D calculation
+2D + 3D calculation
Steady state
2D calculation · steady stateMold PRO · Frame SimulatorMold PRO: linear thermal bridges, Ψ, mould and condensation check.Frame Simulator: windows and curtain walls, according to ISO 10077-2 and ISO 12631.
2D + 3D calculation · steady stateMold PRO 3DPoint thermal bridges and complex constructions too.
+Steady state + transient
2D calculation · steady state + transientMold DYNAMICSteady state as in Mold PRO, plus the transient (time-dependent) calculation.
2D + 3D calculation · steady state + transientMold DYNAMIC 3DSteady state as in Mold PRO 3D, plus the transient calculation, on 3D models too.
Artificial intelligence and automation

Let the program do the work for you

Two ways: ask an AI assistant in plain words, or write a script that repeats the calculation as many times as you like.

An AI assistant connected to the program
MCP CONNECTION · MOLD AND FRAME

The program connected to your AI assistant

Mold Simulator and Frame Simulator 9 include an MCP server, called Heatsim, which makes the program commands available to Claude, ChatGPT, Cursor, VS Code or Codex. The assistant reads the open project and works in the program: it imports the DXF, assigns materials and boundaries, simulates, reads the results and lays out the report.

  • It starts with the Heatsim button in the view bar.
  • It is included: it works with an active Updates & Upgrades subscription.
  • The AI assistant (Claude, ChatGPT or other) is your own service.
The Scripting Module of Mold Simulator and Frame Simulator
SCRIPTING MODULE · PLUGIN

Automatic calculations with scripts

The Scripting Module is a plugin to automate Mold Simulator and Frame Simulator with Python scripts: series of variants, repetitive calculations, reports. Write the procedure once and repeat it on all the cases you need.

  • It is a separate plugin, for those who want to program their own procedures.
  • It is not needed for the connection with the AI assistant.
  • Documentation available in five languages.
The most important new features

From drawing to simulation in fewer steps

Mold Simulator: the templates suggested after loading the DXFMold Simulator
Frame Simulator: the template suggested after loading the DXFFrame Simulator
TEMPLATE · MOLD AND FRAME

Template suggested from the DXF

When the DXF is loaded, the program identifies the suitable templates and highlights them for you: you choose which one to use.

Choosing the Mold Simulator template from the building modelMold Simulator
Choosing the Frame Simulator template from the building modelFrame Simulator
TEMPLATE · MOLD AND FRAME

Template chosen from the building

If you prefer to choose yourself, click the point of the building you are interested in: thermal bridges, window laying and ground floor in Mold; window, roller shutter box and curtain wall in Frame.

Ground floor-wall junction with materials assigned and labelledMold Simulator
Window section after the automatic material assignmentFrame Simulator
MATERIALS · MOLD AND FRAME

Automatic material assignment

A model trained on real sections suggests the material of each area. You confirm the uncertain cases in a table.

Window installation junction with the boundaries assigned: internal wall, internal window and exteriorMold SimulatorFrame Simulator
BOUNDARIES · MOLD AND FRAME

Boundaries with one click

Interior, exterior, ground, unheated room and window laying assigned by the program.

Choosing the thermal bridge on the schematic buildingMold Simulator
BRIDGE GENERATOR · MOLD ONLY

624 ready-made thermal bridges

Choose the junction by clicking on the building. New pitched roof junctions, underground garage and all the UNI 11979 window installation junctions.

Videos · about 3 minutes each

Watch version 9 at work

Much faster simulations

The biggest gain is in 3D, with more stable calculations too.

Five languages

Program, libraries and manuals in English, Italian, French, German and Spanish.

Reports straight to PDF

Unlimited project tags and header images saved in the file.

Material labels

Name and conductivity of each area, readable even in layers a few millimetres thick.

How to move to version 9

With an active Updates & Upgrades subscription version 9 is already included, and with it the AI connection. Do you have version 8 or earlier? You will find all the options on the Software Updates page.